Views: 0 Author: hu Publish Time: 2022-03-17 Origin: dapeng
Ezcad Lite Laser Marking Control System
EZCAD2
Software: EZCAD2
Hardware: FBLI-B-V4, SZLI-B-V4
Connection method: USB
Axis control: one axis
TCP/IP remote control: not supported
REMARK: not supported
Multi-document processing: not supported
Long: not supported
Flight marking: not supported
Camera recording: not supported
Secondary development: not supported
Two-axis linkage: not supported
Offline marking: not supported
2.5D: not supported
3D: not supported
Expansion axis and galvanometer linkage scheme: not supported
Uniform marking: not supported
Quick QR code: not supported
Galvo Protocol: XY2-100
Galvo high-precision correction: 65*65 grid correction points
Galvanometer status reading monitoring: not supported
Laser: Fiber, CO2, YAG
Laser power control linear change: not supported
Laser status read monitoring: not supported
FBLI-B-V4 SZLI-B-V4
Software: Ezcad Lite
Hardware: FBLI-B-LV4, SZLI-B-LV4
Connection method: USB
Axis control: no axis
TCP/IP remote control: support
REMARK: support
Multi-document processing: not supported
Long: not supported
Flight marking: not supported
Camera recording: not supported
Secondary development: not supported
Two-axis linkage: not supported
Offline marking: not supported
2.5D: not supported
3D: not supported
Expansion axis and galvanometer linkage scheme: not supported
Uniform marking: not supported
Quick QR code: not supported
Galvo Protocol: XY2-100
Galvo high-precision correction: 65*65 grid correction points
Galvanometer status reading monitoring: not supported
Laser: Fiber, CO2, YAG
Laser power control linear change: not supported
Laser status read monitoring: not supported
FBLI-B-LV4 SZLI-B-LV4
Software: Ezcad Lite
Hardware: FBLI-B-LV4A, SZLI-B-LV4A
Connection method: USB
Axis control: one axis
TCP/IP remote control: support
REMARK: support
Multi-document processing: not supported
Long: not supported
Flight marking: not supported
Camera recording: not supported
Secondary development: not supported
Two-axis linkage: not supported
Offline marking: not supported
2.5D: not supported
3D: not supported
Expansion axis and galvanometer linkage scheme: not supported
Uniform marking: not supported
Quick QR code: not supported
Galvo Protocol: XY2-100
Galvo high-precision correction: 65*65 grid correction points
Galvanometer status reading monitoring: not supported
Laser: Fiber, CO2, YAG
Laser power control linear change: not supported
Laser status read monitoring: not supported
FBLI-B-LV4A SZLI-B-LV4A