Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.
Item NO.:CWUL-05
Precision:±0.2℃
Voltage:220V
Frequency:50Hz
Refrigerant:R-134a
Reducer:capillary
Pump Power:0.05KW
Tank Capacity:6L
Max.Pump Lift:12M
Max.Pump Flow:13L/min
N.W:23Kgs
G.W:26Kgs
Dimension:58*29*47(L*W*H)
Package Dimension:70*43*58(L*W*H)
High precision water chillers features
1. With environmental refrigerant;
2. Compact size, long working life and simple operation;
3. ±0.2℃ precise temperature control;
4. The temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
5. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
6. Multiple power specifications; CE approval; RoHS approval; REACH approval;
7. Optional heater and water filter.
THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE COMPANY.
UV water chiller units specification
Note: the working current can be different under different working conditions; The above information is for reference only. Please subject to the actual delivered product.
PRODUCT INTRODUCTION
Independent production of sheet metal, evaporator and condenser
Adopt IPG fiber laser for welding and cutting sheet metal.
Temperature control accuracy can reach ±0.2°C.
Ease of moving and water draining.
Inlet and outlet connector equipped
TEMPERATURE CONTROLLER PANEL DESCRIPTION
The intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements.
User also can adjust the water temperature as needed.
Alarm function
(1) Alarm Display:
When alarm occurs, the error code and the temperature will be alternately displayed.
(2) To suspend the alarm:
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.
In order to guarantee the equipment will not be effected while abnormal situation happens on the chiller, CWUL series chillers possess alarm protection function.
1. Alarm output terminals and wiring diagram.
2. Alarm causes and working status table.
Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.
Laser Nozzles Ceramic Holders Collimation/Focus lens Tube Tooling Kits Goggles Ceramic Locker Ring Seal Ring/Washer